Float Switches〈LR、NV、BV、NK、GL and other ship association forms approval products〉
Liquid surface in a tank is detected by the float, and it is used as switches for sending the warning signals.

S-K16ES-N
(Production range)
Mounting&features | Tank side mounting, small float type |
---|---|
Nominal diameter | JIS 5K-50A, JIS 5K-65A |
Temperature of fluid | 0 to 100℃ (Heat-resistant type:150℃) |
Pressure | MAX.1.0MPa |
Pressure switch capacity | 10A-250VAC |

S-K16ES
(Production range)
Mounting&features | Tank side mounting, standard float type |
---|---|
Nominal diameter | JIS 5K-65A,JIS 10K-65A ANSI 150PSI-2 1/2B |
Temperature of fluid | 0 to 100℃ (Heat-resistant type:150℃) |
Pressure | MAX.1.0MPa |
Pressure switch capacity | 10A-250VAC 0.4A-125VDC |

S-K16ES-S40
(Production range)
Mounting&features | Tank side mounting, small float type |
---|---|
Nominal diameter | JIS 5K-40A,JIS 10K-40A ANSI 150PSI-1 1/2B |
Temperature of fluid | 0 to 100℃ |
Pressure | MAX.1.0MPa |
Pressure switch capacity | 3A-250VAC 0.4A-125VDC |

S-K16ES-DR
(Production range)
Mounting&features | Tank side mounting with test device type |
---|---|
Nominal diameter | JIS 5K-65A, ANSI 150PSI-2 1/2B |
Temperature of fluid | 0 to 100℃ (Heat-resistant type:150℃) |
Pressure | MAX.1.0MPa |
Pressure switch capacity | 3A-250VAC 0.4A-125VDC |

S-K16ES-M
(Production range)
Mounting&features | Tank inside mounting with air-operated device type |
---|---|
Nominal diameter | JIS 5K-50A,JIS 10K-50A ANSI 150PSI-2B |
Temperature of fluid | -50 to 60℃ |
Pressure | MAX.1.0MPa |
Pressure switch capacity | 3A-250VAC 0.4A-125VDC |

S-K16AH,S-K16AL
(Production range)
Mounting&features | Tank top mounting type, standard float type |
---|---|
Nominal diameter | JIS 5K-100A,JIS 10K-100A ANSI 150PSI-4B |
Temperature of fluid | 0 to 100℃ |
Pressure | MAX.1.0MPa |
Pressure switch capacity | 10A-250VAC 0.4A-125VDC |

S-K16KSG
(Production range)
Mounting&features | Tank top mounting, small float type |
---|---|
Nominal diameter | JIS 5K-65A,JIS 10K-65A ANSI 150PSI-2 1/2B |
Temperature of fluid | 0 to 100℃ |
Pressure | MAX.1.0MPa |
Pressure switch capacity | 0.2A-240VAC 0.68A-125VDC |

S-K16BH,S-K16BL
(Production range)
Mounting&features | Tank side mounting with chamber type |
---|---|
Nominal diameter | JIS 10K-25A to 50A ANSI 150PSI-1B to 2B |
Temperature of fluid | 0 to 100℃ |
Pressure | MAX.1.0MPa |
Pressure switch capacity | 10A-250VAC 0.4A-125VDC |

S-K16FE
(Production range)
Mounting&features | Tank side mounting with chamber type |
---|---|
Nominal diameter | JIS 16K-25A ANSI 300PSI-1B |
Temperature of fluid | 0 to 100℃ |
Pressure | MAX.1.0MPa |
Pressure switch capacity | 10A-250VAC 0.4A-125VDC |