Float Gauges
Liquid surface in the tank is detected by the float, and the surface level is displayed on the gauges.

S-K170
(Production range)
Characteristic | Highly accurate rolling-up type float gauges with reduced scale indication by a constant torque spring |
---|---|
Tank height | 1M to 6M |
Specific gravity | 0.7 to 1.2 |
Temperature of fluid | 0 to 100℃ |
Alarm switch | MAX. 4 contacts |
Japanese patent number:4061323

S-K175C
(Production range)
Characteristic | Highly accurate rolling-up type float gauges with reduced scale indication by a constant torque spring |
---|---|
Tank height | 0.9M to 6M |
Specific gravity | 0.7 to 1.2 |
Temperature of fluid | 0 to 100℃ |
Alarm switch | MAX. 6 contacts |

S-K179S
(Production range)
Characteristic | Highly accurate and durable rolling-up type float gauges with scale indication by a wind-up spring. |
---|---|
Tank height | 0.9M to 6M |
Specific gravity | 0.7 to 1.2 |
Temperature of fluid | 0 to 100℃ |
Alarm switch | MAX. 6 contacts |

S-K17S(Tank top mounting, reduced scale indication)
Model code | Specifications |
---|---|
S-K17SC | Sealed type, Operation: MAX. 70℃ |
S-K17SHC | Sealed type with intermediate pipe(Load pipe), Operation: MAX. 70℃ |
S-K17SC-HP | Sealed type, Operation: Air tightness of 0.1MPa, MAX. 230℃ |
S-K17SHC-HP | Sealed type with intermediate pipe(Load pipe), Operation: Air tightness of 0.1MPa, MAX. 230℃ |

S-K17A(Tank top mounting, direct scale indication)
Model code | Specifications |
---|---|
S-K17AHC | Sealed type, Operation: MAX. 70℃ |
S-K17AHC-HP | Sealed type, Operation: Air tightness of 0.1MPa, MAX. 230℃ |

S-K17B(Tank side mounting, direct scale indication)
Model code | Specifications |
---|---|
S-K17B | Open type |